FASTASeq 300
FASTASeq 300 is a desktop high-throughput sequencing platform that focuses on targeted sequencing and whole-genome low-pass sequencing. Its innovative breakthroughs in sequencing chemistry, high-density flow cell, fluid design and base identification algorithms bring users more flexibility, more consistent data quality and faster delivery of high-quality data.
* For Research Use Only. Not intended for use in diagnostic or clinical procedures. Not available in all countries.
Highlights
Performance Parameters
Applications
Specification Parameters
Ordering information
Documents
Documents

  • Ultra-simple Operation

    Ready-to-use reagent kit design

    Automatic wash procedure after operation

    Automatic identification of RFID consumables

  • Ultimate Flexibility

    Support five types of flow cells and multiple read lengths

    Split-channel sample loading

    Multi-time-point(MTO) data output

  • Ultra-fast Delivery

    4 hours for SE50

    9.5 hours for PE75

    13 hours for PE150

  • Ultra-high Quality Data

    Compatible with advanced optical module inside

    Using four color chemistry, reach Q30≥90%

FASTASeq 300 V2.0 & 3.0 Kit
Flow Cell Lane Throughput(Reads/FC) Type Read Length Data output1 Q301 TAT2(h)
FCL 2 50M 100cycles SE100 5Gb ≥90% 5.5 hr
FCX 2 100M 400cycles SE400 40Gb ≥80% 31.5 hr
600cycles PE300 60Gb ≥85% 46.5 hr
800cycles PE400 40Gb ≥80% 61 hr3
FCM 4 125M 75cycles SE75 9.4Gb ≥90% 4.5 hr
150cycles PE75 18.8Gb 9.5 hr
300cycles PE150 37.5Gb 13 hr
FCH 4 280M 75cycles SE75 21Gb 5 hr
150cycles PE75 42Gb 9.5 hr
300cycles PE150 84Gb 16 hr
FCP 4 500M 75cycles SE75 37.5Gb 7.5 hr
150cycles PE75 75Gb 14 hr
300cycles PE150 150Gb 24 hr


1. This parameter is obtained based on the average of multiple test resuts of GeneMind P3 standard library. The data output and the proportion of high-quality data are affected by factors such as sample type, sample quality and effective flow cell utilization. The actual performance may vary.

2. The TAT (tumaround time)fora standard run (paired-end 8+8 indexing)encompasses the entire process from library loading to the generationtion of base-called sequence files.

3. PE400 sequencing requires two kits with manual kit replacement in between, the time excludes manual replacement time.

Applications Read Length Data/sample Number of samples/FC
FCL-50M FCX-100M FCM-125M FCH-280M FCP-500M
Oncology Panel (30genes)-Tissue PE150 6 Gb / / 20 48 96
Oncology Panel (30genes)-Plasma PE150 50 Gb / / 4 8 16
NIPT Basic SE75 5M reads 12 / 24 48 96
NIPT Standard SE75 7M reads / / 16 32 64
NIPT Plus SE75 10M reads / / 12 24 48
NIPT Pro SE75 20M reads / / / / 20
TB-tNGS SE100 2M reads 192 / 36 96 192
PGT-A SE75 5M Reads 6 / 16 36 64
CNVseq PE150 20M reads / / 4 12 24
HLA (11gene) PE150 0.6 Gb / / 48 96 192
16S/18S/ITS PE300 0.2M reads / 400 / / /
Forensic/STR SE400 2M reads / 40 / /

/


The above sample numbers for different applications are only for reference. User need to adjust the sample numbers according to the actual experiment.


Specification
Dimensions 684mm x 644mm x 615mm
Weight 145kg
Operating Power 2000VA
Power Requirements 100V-240VAC,50/60Hz
Operating Environment Temperature: 19℃-25℃
Humidity: 20%-80%(non-condensing)
Altitude: 0~3000m
Instrument Control Computer CPU: Intel XeonSilver4126
Memory: 32GB DDR4*6
Solid-state Drive: 480GB
Hard Drive: 2TB
Operating System: windows10 x64
Catalog Number Product name Specification
SQ00020 FASTASeq 300 Sequencing System Set RUO
S000290 FASTASeq 300 Sequencing Kit V2.0(FCL-D SE100-D) FCL-D SE100-D
S000277 FASTASeq 300 Sequencing Kit V2.0(FCX 600cycles) FCX 600cycles
S000406 FASTASeq 300 Sequencing Kit V2.0(FCX 400cycles) FCX 400cycles
S000610 FASTASeq 300 Sequencing Kit V2.0 (FCX PE400) FCX PE400
S000447 FASTASeq 300 Sequencing Kit V3.0(FCM-D SE075-D) FCM-D SE075-D
S000448 FASTASeq 300 Sequencing Kit V3.0(FCM 150cycles) FCM 150cycles
S000449 FASTASeq 300 Sequencing Kit V3.0(FCM 300cycles) FCM 300cycles
S000450 FASTASeq 300 Sequencing Kit V3.0(FCH-D SE075-D) FCH-D SE075-D
S000451 FASTASeq 300 Sequencing Kit V3.0(FCH 150cycles) FCH 150cycles
S000452 FASTASeq 300 Sequencing Kit V3.0(FCH 300cycles) FCH 300cycles
S000453 FASTASeq 300 Sequencing Kit V3.0(FCP-D SE075-D) FCP-D SE075-D
S000454 FASTASeq 300 Sequencing Kit V3.0(FCP 150cycles) FCP 150cycles
S000455 FASTASeq 300 Sequencing Kit V3.0(FCP 300cycles) FCP 300cycles



For Research Use Only. Not intended for use in diagnostic or clinical procedures. Not available in all countries.