Ready-to-use reagent kit design
Automatic wash procedure after operation
Automatic identification of RFID consumables
Support five types of flow cells and multiple read lengths
Split-channel sample loading
Multi-time-point(MTO) data output
4 hours for SE50
9.5 hours for PE75
13 hours for PE150
Compatible with advanced optical module inside
Using four color chemistry, reach Q30≥90%
| FASTASeq 300 V2.0 & 3.0 Kit | |||||||
| Flow Cell | Lane | Throughput(Reads/FC) | Type | Read Length | Data output1 | Q301 | TAT2(h) |
| FCL | 2 | 50M | 100cycles | SE100 | 5Gb | ≥90% | 5.5 hr |
| FCX | 2 | 100M | 400cycles | SE400 | 40Gb | ≥80% | 31.5 hr |
| 600cycles | PE300 | 60Gb | ≥85% | 46.5 hr | |||
| 800cycles | PE400 | 40Gb | ≥80% | 61 hr3 | |||
| FCM | 4 | 125M | 75cycles | SE75 | 9.4Gb | ≥90% | 4.5 hr |
| 150cycles | PE75 | 18.8Gb | 9.5 hr | ||||
| 300cycles | PE150 | 37.5Gb | 13 hr | ||||
| FCH | 4 | 280M | 75cycles | SE75 | 21Gb | 5 hr | |
| 150cycles | PE75 | 42Gb | 9.5 hr | ||||
| 300cycles | PE150 | 84Gb | 16 hr | ||||
| FCP | 4 | 500M | 75cycles | SE75 | 37.5Gb | 7.5 hr | |
| 150cycles | PE75 | 75Gb | 14 hr | ||||
| 300cycles | PE150 | 150Gb | 24 hr | ||||
1. This parameter is obtained based on the average of multiple test resuts of GeneMind P3 standard library. The data output and the proportion of high-quality data are affected by factors such as sample type, sample quality and effective flow cell utilization. The actual performance may vary.
2. The TAT (tumaround time)fora standard run (paired-end 8+8 indexing)encompasses the entire process from library loading to the generationtion of base-called sequence files.
3. PE400 sequencing requires two kits with manual kit replacement in between, the time excludes manual replacement time.
| Applications | Read Length | Data/sample | Number of samples/FC | ||||
| FCL-50M | FCX-100M | FCM-125M | FCH-280M | FCP-500M | |||
| Oncology Panel (30genes)-Tissue | PE150 | 6 Gb | / | / | 20 | 48 | 96 |
| Oncology Panel (30genes)-Plasma | PE150 | 50 Gb | / | / | 4 | 8 | 16 |
| NIPT Basic | SE75 | 5M reads | 12 | / | 24 | 48 | 96 |
| NIPT Standard | SE75 | 7M reads | / | / | 16 | 32 | 64 |
| NIPT Plus | SE75 | 10M reads | / | / | 12 | 24 | 48 |
| NIPT Pro | SE75 | 20M reads | / | / | / | / | 20 |
| TB-tNGS | SE100 | 2M reads | 192 | / | 36 | 96 | 192 |
| PGT-A | SE75 | 5M Reads | 6 | / | 16 | 36 | 64 |
| CNVseq | PE150 | 20M reads | / | / | 4 | 12 | 24 |
| HLA (11gene) | PE150 | 0.6 Gb | / | / | 48 | 96 | 192 |
| 16S/18S/ITS | PE300 | 0.2M reads | / | 400 | / | / | / |
| Forensic/STR | SE400 | 2M reads | / | 40 | / | / |
/ |
The above sample numbers for different applications are only for reference. User need to adjust the sample numbers according to the actual experiment.
| Specification | |
| Dimensions | 684mm x 644mm x 615mm |
| Weight | 145kg |
| Operating Power | 2000VA |
| Power Requirements | 100V-240VAC,50/60Hz |
| Operating Environment | Temperature: 19℃-25℃ |
| Humidity: 20%-80%(non-condensing) | |
| Altitude: 0~3000m | |
| Instrument Control Computer | CPU: Intel XeonSilver4126 |
| Memory: 32GB DDR4*6 | |
| Solid-state Drive: 480GB | |
| Hard Drive: 2TB | |
| Operating System: windows10 x64 | |
| Catalog Number | Product name | Specification |
| SQ00020 | FASTASeq 300 Sequencing System Set | RUO |
| S000290 | FASTASeq 300 Sequencing Kit V2.0(FCL-D SE100-D) | FCL-D SE100-D |
| S000277 | FASTASeq 300 Sequencing Kit V2.0(FCX 600cycles) | FCX 600cycles |
| S000406 | FASTASeq 300 Sequencing Kit V2.0(FCX 400cycles) | FCX 400cycles |
| S000610 | FASTASeq 300 Sequencing Kit V2.0 (FCX PE400) | FCX PE400 |
| S000447 | FASTASeq 300 Sequencing Kit V3.0(FCM-D SE075-D) | FCM-D SE075-D |
| S000448 | FASTASeq 300 Sequencing Kit V3.0(FCM 150cycles) | FCM 150cycles |
| S000449 | FASTASeq 300 Sequencing Kit V3.0(FCM 300cycles) | FCM 300cycles |
| S000450 | FASTASeq 300 Sequencing Kit V3.0(FCH-D SE075-D) | FCH-D SE075-D |
| S000451 | FASTASeq 300 Sequencing Kit V3.0(FCH 150cycles) | FCH 150cycles |
| S000452 | FASTASeq 300 Sequencing Kit V3.0(FCH 300cycles) | FCH 300cycles |
| S000453 | FASTASeq 300 Sequencing Kit V3.0(FCP-D SE075-D) | FCP-D SE075-D |
| S000454 | FASTASeq 300 Sequencing Kit V3.0(FCP 150cycles) | FCP 150cycles |
| S000455 | FASTASeq 300 Sequencing Kit V3.0(FCP 300cycles) | FCP 300cycles |
For Research Use Only. Not intended for use in diagnostic or clinical procedures. Not available in all countries.