SURFSeq Q
SURFSeq Q is an ultra-high throughput sequencer with a worldwide superb daily data output capacity. By integrating several innovative technologies, such as high-speed chemistry, new patterned array sequencing flow cell, AI base recognition algorithm, and other innovative technologies, SURFSeq Q can achieve the Q40 score >=90% with a powerful productivity of 9Tb per day in a single run. Its superior data delivery capabilities and high accuracy can efficiently support scientific discovery and sequencing services, such as extensive population cohort studies and single-cell and spatial omics research.
* For Research Use Only. Not intended for use in diagnostic or clinical procedures. Not available in all countries.
Highlights
Performance Parameters
Applications
Specification Parameters
Ordering Information
Documents
Documents

  • Super Delivery Capacity

    Ultra-high data throughput: 14 Tb/Run

    Ultra-high production efficiency: 9 Tb/day, over 23,000 WGS (30x)/ year

  • Super High Data Quality

    Innovative sequencing chemistry and Al base-calling algorithm

    Q40 level data output can be achieved

  • User-friendly

    Fully automated independent eight-channel sample loading

    Supports break-point resumption for worry-free project operation

  • Super Flexible

    Customizable sequencing order and data batch delivery

    Automatic cleaning after unloading and automatic reagent discharge

SURFSeq Q V1.0 Kit
Flow Cell Lane Throughput(Reads/FC) Type Read Length

Data output1

(FC×2)

Q301

Q401 TAT2
(1 FC)
FCM 4 11.7B 50 cycles SE50 0.6 Tb×2 Q30≥90% Q40≥90% 10 hr
100 cycles SE100/PE50 1.2 Tb×2 13 hr
200 cycles PE100 2.3 Tb×2 19 hr
300 cycles PE150 3.5 Tb×2 24 hr
FCH 8 23.3B 50 cycles SE50 1.2 Tb×2 17 hr
100cycles SE100/PE50 2.3 Tb×2 22 hr
200cycles PE100 4.7 Tb×2 29 hr
300cycles PE150 7 Tb×2 36 hr

1. This parameter is obtained based on the average of multiple test resuts of GeneMind P3 standard library. The data output and the proportion of high-quality data are affected by factors such as sample type, sample quality and effective flow cell utilization. The actual performance may vary.

2. The TAT (tumaround time)for a standard run (paired-end 8+8 indexing)encompasses the entire process from library loading to the generationtion of base-called sequence files.


Applications Read Length Data/sample Number of samples/FC
FCM-11700M FCH-23400M
Oncology Panel (580genes)-Plasma PE150 50 Gb 48 96
WES (100X) PE150 12 Gb 256 512
WGS (30X) PE150 110 Gb 26 52
Single cell 3' RNA-seq PE150 120 Gb 24

48


The above sample numbers for different applications are only for reference. User need to adjust the sample numbers according to the actual experiment.

Specification
Dimensions W × D × H 975 mm × 921 mm×1570 mm
Weight < 500 kg
Power requirements < 6000 W
200-240 V~,50/60 Hz
Operating environment Temperature: 19 ℃ – 25 ℃
non-condensing:20‒80% relative humidity
Instrument control computer Altitude:≤2000 m
CPU:Intel Xeon Gold 6326 ×2
Memory: 2 TB
Solid-state drive: 3.7 TB
Hard disk drive: 76.3 TB
Operating system: Windows 10 ×64

Catalog Number Product Name Specification
SQ00066 SURFSeq Q Sequencing System Set RUO
S000379 SURFSeq Q Sequencing Kit V1.0 (FCM 50cycles) FCM 50cycles
S000380 SURFSeq Q Sequencing Kit V1.0 (FCM 100cycles) FCM 100cycles
S000381 SURFSeq Q Sequencing Kit V1.0 (FCM 200cycles) FCM 200cycles
S000382 SURFSeq Q Sequencing Kit V1.0 (FCM 300cycles) FCM 300cycles
S000383 SURFSeq Q Sequencing Kit V1.0 (FCH 50cycles) FCH 50cycles
S000384 SURFSeq Q Sequencing Kit V1.0 (FCH 100cycles) FCH 100cycles
S000385 SURFSeq Q Sequencing Kit V1.0 (FCH 200cycles) FCH 200cycles
S000386 SURFSeq Q Sequencing Kit V1.0 (FCH 300cycles) FCH 300cycles


For Research Use Only. Not intended for use in diagnostic or clinical procedures. Not available in all countries. 


Welcome to GeneMind
This website uses cookies to improve your overall experience, make your next visit to the river website easier and faster, and provide you with better service. Please refer to the Privacy Policy.
Reject
Accept All