3 hours for SE100, 6.8 hours for PE150
Lightning chemistry plus reduce cycle time 50%
User-friendly Interface
7 minutes NGS run preparation
Reduce reagent consumption 70%
Sequencing on demand
Smart waste sorting and processing design
RT shipping and stroage for load-and-go reagent
| Flow Cell | Lane | Throughput(Reads/FC) | Type | Read Length | Data Output2 | Q302 | TAT(h)3 |
| FCL | 1 | 20 M | SE100-D | SE100 | 2 Gb | ≥90% | ~3.0 hrs |
| 100 cycles | PE50 | 2 Gb | ~4.0 hrs | ||||
| 300 cycles | PE150 | 6 Gb | ~6.8 hrs | ||||
| 600 cycles | SE400 | 8 Gb | ~11.0 hrs | ||||
| PE300 | 12 Gb | ~15.0 hrs | |||||
| FCM | 1 | 40 M | SE100-D | SE100 | 4 Gb | ~3.5 hrs | |
| 100 cycles | PE50 | 4 Gb | ~4.5 hrs | ||||
| 300 cycles | PE150 | 12 Gb | ~7.5 hrs | ||||
| 600 cycles | SE400 | 16 Gb | ~12.0 hrs | ||||
| PE300 | 24 Gb | ~17.0 hrs | |||||
| FCH1 | 1 | 80 M | SE100-D | SE100 | 8 Gb | ~4.5 hrs | |
| 100 cycles | PE50 | 8 Gb | ~5.5 hrs | ||||
| 300 cycles | PE150 | 24 Gb |
~9.0 hrs |
1. The FCH 80M flow cell will be available in November 2026.
2. This parameter is obtained based on the average of multiple test results of GeneMind P3 standard library. The data output and the proportion of high-quality data are affected by factors such as sample type, sample quality and effective flow cell utilization. The actual performance may vary.
3. The TAT (turnaround time) for a standard run (paired-end 8+8 indexing) encompasses the entire process from library loading to the generation of base-called sequence files.
| Application | Data/sample | FCL-20 M | FCM- 40 M |
| mNGS (based on probe capture) | 2 M Reads/sample | 8 | 16 |
| TB-tNGS | 2 M Reads/sample | 8 | 16 |
| Small Oncology Panel(Tissue) | 1 Gb/sample | 4 | 8 |
| WES | 8-12 Gb/sample | / | 1 |
| HLA Typing | 0.2 Gb/sample | 24 | 48 |
| PGT-A | 5 M Reads/sample | 2 | 4 |
| Microbial WGS | 1 Gb/sample | 4 | 8 |
| NGS Library QC | 0.1 Gb/sample | 160 | 320 |
| Specification | |
| Dimensions (W × D × H) | 626 mm × 580 mm× 575 mm |
| Weight | about 100 kg |
| Power requirements | ≤ 1000 VA |
| 200-240 V~, 50/60 Hz | |
| Operating environment | Temperature: 19 ℃ – 25 ℃ |
| non-condensing:20‒80% relative humidity | |
| Altitude:≤3000 m | |
| Instrument control computer | CPU: Gen Inter(R) Core(TM) i7-13700T |
| Memory: 64 GB | |
| Hard drive: 4 TB | |
| Operating system: Windows 10 | |
| Catalog Number | Product name | Specification |
| SQ00075 | FASTASeq S Sequencing System Set | RUO |
| S000515 | FASTASeq S Sequencing Kit V1.0 (FCL-D SE100-D) | FCL-D SE100-D |
| S000516 | FASTASeq S Sequencing Kit V1.0 (FCL 100cycles) | FCL 100cycles |
| S000517 | FASTASeq S Sequencing Kit V1.0 (FCL 300cycles) | FCL 300cycles |
| S000534 | FASTASeq S Sequencing Kit V2.0 (FCL 600 cycles)* | FCL 600 cycles |
| S000518 | FASTASeq S Sequencing Kit V1.0 (FCM-D SE100-D) | FCM-D SE100-D |
| S000519 | FASTASeq S Sequencing Kit V1.0 (FCM 100cycles) | FCM 100cycles |
| S000520 | FASTASeq S Sequencing Kit V1.0 (FCM 300cycles) | FCM 300cycles |
| S000536 | FASTASeq S Sequencing Kit V2.0 (FCM 600 cycles)* |
FCM 600 cycles |
*The 600-cycle kit is compatible with both SE400 and PE300 sequencing.
**For Research Use Only. Not intended for use in diagnostic or clinical procedures. Not available in all countries.