FASTASeq S
FASTASeq S is an ultra-fast sequencer, the platform delivers results from library preparation to data output in: 3 hours for SE100, and 6.8 hours for PE150. The FASTASeq S integrates an ultra-high-speed fluid system and a new enzyme reaction system, dramatically improving sequencing efficiency. Enhanced by an AI-powered base-calling algorithm, the platform achieves exceptional signal recognition accuracy and speed. Optimized flow cell surface amplification technology further ensures high-quality data output——even with nanogram-level trace samples.
* For Research Use Only. Not intended for use in diagnostic or clinical procedures. Not available in all countries.
Highlights
Performance Parameters
Applications
Specification Parameters
Ordering information
Documents
Documents

  • Swift

    3 hours for SE100, 6.8 hours for PE150

    Lightning chemistry plus reduce cycle time 50%

  • Simple

    User-friendly Interface

    7 minutes NGS run preparation

  • Saving

    Reduce reagent consumption 70%

    Sequencing on demand

  • Social Responsible

    Smart waste sorting and processing design

    RT shipping and stroage for load-and-go reagent

Flow Cell Lane Throughput(Reads/FC) Type Read Length Data Output2 Q302 TAT(h)3
FCL 1 20 M SE100-D SE100 2 Gb ≥90% ~3.0 hrs
100 cycles PE50 2 Gb ~4.0 hrs
300 cycles PE150 6 Gb ~6.8 hrs
600 cycles SE400 8 Gb ~11.0 hrs
PE300 12 Gb ~15.0 hrs
FCM 1 40 M SE100-D SE100 4 Gb ~3.5 hrs
100 cycles PE50 4 Gb ~4.5 hrs
300 cycles PE150 12 Gb ~7.5 hrs
600 cycles SE400 16 Gb ~12.0 hrs
PE300 24 Gb ~17.0 hrs
FCH1 1 80 M SE100-D SE100 8 Gb ~4.5 hrs
100 cycles PE50 8 Gb ~5.5 hrs
300 cycles PE150 24 Gb

~9.0 hrs



1. The FCH 80M flow cell will be available in November 2026.


2. This parameter is obtained based on the average of multiple test results of GeneMind P3 standard library. The data output and the proportion of high-quality data are affected by factors such as sample type, sample quality and effective flow cell utilization. The actual performance may vary.


3. The TAT (turnaround time) for a standard run (paired-end 8+8 indexing) encompasses the entire process from library loading to the generation of base-called sequence files.


Application Data/sample FCL-20 M FCM- 40 M
mNGS (based on probe capture) 2 M Reads/sample 8 16
TB-tNGS 2 M Reads/sample 8 16
Small Oncology Panel(Tissue) 1 Gb/sample 4 8
WES 8-12 Gb/sample / 1
HLA Typing 0.2 Gb/sample 24 48
PGT-A 5 M Reads/sample 2 4
Microbial WGS 1 Gb/sample 4 8
NGS Library QC 0.1 Gb/sample 160 320

Specification
Dimensions (W × D × H) 626 mm × 580 mm× 575 mm
Weight about 100 kg
Power requirements ≤ 1000 VA
200-240 V~, 50/60 Hz
Operating environment Temperature: 19 ℃ – 25 ℃
non-condensing:20‒80% relative humidity
Altitude:≤3000 m
Instrument control computer CPU: Gen Inter(R) Core(TM) i7-13700T
Memory: 64 GB
Hard drive: 4 TB
Operating system: Windows 10

Catalog Number Product name Specification
SQ00075 FASTASeq S Sequencing System Set RUO
S000515 FASTASeq S Sequencing Kit V1.0 (FCL-D SE100-D) FCL-D SE100-D
S000516 FASTASeq S Sequencing Kit V1.0 (FCL 100cycles) FCL 100cycles
S000517 FASTASeq S Sequencing Kit V1.0 (FCL 300cycles) FCL 300cycles
S000534 FASTASeq S Sequencing Kit V2.0 (FCL 600 cycles)* FCL 600 cycles
S000518 FASTASeq S Sequencing Kit V1.0 (FCM-D SE100-D) FCM-D SE100-D
S000519 FASTASeq S Sequencing Kit V1.0 (FCM 100cycles) FCM 100cycles
S000520 FASTASeq S Sequencing Kit V1.0 (FCM 300cycles) FCM 300cycles
S000536 FASTASeq S Sequencing Kit V2.0 (FCM 600 cycles)*

FCM 600 cycles


*The 600-cycle kit is compatible with both SE400 and PE300 sequencing.


**For Research Use Only. Not intended for use in diagnostic or clinical procedures. Not available in all countries.