GenoLab M
The high-throughput sequencing system GenoLab M adopts the surface-restricted fluorescence sequencing technique (SURFseq) based on surface amplification to identify the optical signals of bases. Its sequencing-by-synthesis approach delivers fast speed, high flexibility, high accuracy, and low cost. GenoLab M can be configured to run 1 flow cell alone or 2 flow cells simultaneously---enabling a scalable solution tailored to your specific research needs. With single or dual flow cell options, the system can be tuned to meet output needs ranging from 37Gb to 300Gb per run, supporting a wide range of applications.
* For Research Use Only. Not intended for use in diagnostic or clinical procedures. Not available in all countries.
Highlights
Performance Parameters
Applications
Specification Parameters
Ordering Information
Documents
Documents

  • High Integration

    Libraries can be directly used for sequencing after preparation

    Multiple throughputs and read lengths available

  • High Accuracy

    Combined with a high-sensitivity fluorescence signal detection system to maximize sequencing accuracy

  • High Compatibility

    Compatible to mainstream NGS libraries and bioinformatics analysis software

    Compatible with GeneMind bioinformatics analysis software

  • High Flexibility

    Pre-mixed cartridges, integrating amplification and sequencing

    Single/dual chips rolling on the machine

GenoLab M V4.0 Kit
Flow Cell Lane Throughput(Reads/FC) Type Read Length Data output1 Q301 TAT2(h)
FCM 4 250M 75cycles SE75 18Gb ≥85% 13 hr
150cycles PE75 37.5Gb 22 hr
300cycles PE150 75Gb 38 hr
FCH 4 500M 75cycles SE75 37.5Gb 15 hr
150cycles PE75 75Gb 28 hr
300cycles PE150 150Gb

50 hr


1. This parameter is obtained based on the average of multiple test resuts of GeneMind P3 standard library. The data output and the proportion of high-quality data are affected by factors such as sample type, sample quality and effective flow cell utilization. The actual performance may vary.

2. The TAT (tumaround time)fora standard run (paired-end 8+8 indexing)encompasses the entire process from library loading to the generationtion of base-called sequence files.


Applications Read Length Data/sample Number of samples/FC
FCH-250M FCH-500M
Oncology Panel (30genes)-Tissue PE150 6 Gb 48 96
Oncology Panel (30genes)-Plasma PE150 50 Gb 8 16
NIPT Basic SE75 5M reads 48 96
NIPT Standard SE75 7M reads 32 64
NIPT Plus SE75 10M reads 24 48
NIPT Pro SE75 20M reads / 20
TB-tNGS SE100 2M reads 96 192
PGT-A SE75 5M Reads 36 64
CNVseq PE150 20M reads 12 24
HLA (11gene) PE150 0.6 Gb 96 192


The above sample numbers for different applications are only for reference. User need to adjust the sample numbers according to the actual experiment.

Specification
Dimensions 1170mm(L)×690mm(W)×600mm(H)
Weight 200kg
Operating Environment Temperature: 19℃-25℃
Humidity: 20%-80% relative humidity, non-condensing
Altitude: below 300m
Instrument Control Computer Operating System: Windows 10
CPU: IntelXeon Silver 4216 2.1GHz
Memory: 32GB*6 DDR4
Hard Drive1: 1TB SSD
Hard Drive2: 10TB HDD
GenoLab M V4.0 Kit
Catalog Number Product Name Specification
SQ00010 GenoLab M Sequencing System Set RUO
S000243 GenoLab M Sequencing Kit V4.0(FCM-D SE075-D) FCM-D SE075-D
S000244 GenoLab M Sequencing Kit V4.0(FCM 150cycles) FCM 150cycles
S000245 GenoLab M Sequencing Kit V4.0(FCM 300cycles) FCM 300cycles
S000246 GenoLab M Sequencing Kit V4.0(FCH-D SE075-D) FCH-D SE075-D
S000247 GenoLab M Sequencing Kit V4.0(FCH 150cycles) FCH 150cycles
S000248 GenoLab M Sequencing Kit V4.0(FCH 300cycles) FCH 300cycles


For Research Use Only. Not intended for use in diagnostic or clinical procedures. Not available in all countries.

Welcome to GeneMind
This website uses cookies to improve your overall experience, make your next visit to the river website easier and faster, and provide you with better service. Please refer to the Privacy Policy.
Reject
Accept All