3 hours for SE100, 6.8 hours for PE150
Lightning chemistry plus reduce cycle time 50%
User-friendly Interface
7 minutes NGS run preparation
Reduce reagent consumption 70%
Sequencing on demand
Smart waste sorting and processing design
RT shipping and storage for load-and-go reagent
| Flow Cell | Lane | Throughput(Reads/FC) | Type | Read Length | Data Output2 | Q302 | TAT(h)3 |
| FCL | 1 | 20 M | SE100-D | SE100 | 2 Gb | ≥90% | ~3.0 hrs |
| 100 cycles | PE50 | 2 Gb | ~4.0 hrs | ||||
| 300 cycles | PE150 | 6 Gb | ~6.8 hrs | ||||
| 600 cycles | SE400 | 8 Gb | ~11.0 hrs | ||||
| PE300 | 12 Gb | ~15.0 hrs | |||||
| FCM | 1 | 40 M | SE100-D | SE100 | 4 Gb | ~3.5 hrs | |
| 100 cycles | PE50 | 4 Gb | ~4.5 hrs | ||||
| 300 cycles | PE150 | 12 Gb | ~7.5 hrs | ||||
| 600 cycles | SE400 | 16 Gb | ~12.0 hrs | ||||
| PE300 | 24 Gb | ~17.0 hrs | |||||
| FCH1 | 1 | 80 M | SE100-D | SE100 | 8 Gb | ~4.5 hrs | |
| 100 cycles | PE50 | 8 Gb | ~5.5 hrs | ||||
| 300 cycles | PE150 | 24 Gb |
~9.0 hrs |
1. The FCH 80M flow cell will be available in March 2027.
2. This parameter is obtained based on the average of multiple test results of GeneMind P3 standard library. The data output and the proportion of high-quality data are affected by factors such as sample type, sample quality and effective flow cell utilization. The actual performance may vary.
3. The TAT (turnaround time) for a standard run (paired-end 8+8 indexing) encompasses the entire process from library loading to the generation of base-called sequence files.
| Application | Data/sample | FCL-20 M | FCM- 40 M |
| mNGS (based on probe capture) | 2 M Reads/sample | 8 | 16 |
| TB-tNGS | 2 M Reads/sample | 8 | 16 |
| Small Oncology Panel(Tissue) | 1 Gb/sample | 4 | 8 |
| WES | 8-12 Gb/sample | / | 1 |
| HLA Typing | 0.2 Gb/sample | 24 | 48 |
| PGT-A | 4 M Unique Reads/sample | 3 | 6 |
| Microbial WGS | 1 Gb/sample | 4 | 8 |
| NGS Library QC | 0.1 Gb/sample | 160 | 320 |
| Specification | |
| Dimensions (W × D × H) | 626 mm × 580 mm× 575 mm |
| Weight | about 100 kg |
| Power requirements | ≤ 1000 VA |
| 200-240 V~, 50/60 Hz | |
| Operating environment | Temperature: 19 ℃ – 25 ℃ |
| non-condensing:20‒80% relative humidity | |
| Altitude:≤3000 m | |
| Instrument control computer | CPU: Gen Inter(R) Core(TM) i7-13700T |
| Memory: 64 GB | |
| Hard drive: 4 TB | |
| Operating system: Windows 10 | |
| Catalog Number | Product name | Specification |
| S000078 | FASTASeq S Dx Sequencing System Set | CE-IVD |
| S000495 | FASTASeq S Dx Universal Reaction Kit for Sequencing | S-1 FCL-D 100-D |
| S000496 | FASTASeq S Dx Universal Reaction Kit for Sequencing | S-1 FCL 100 |
| S000497 | FASTASeq S Dx Universal Reaction Kit for Sequencing | S-1 FCL 300 |
| S000498 | FASTASeq S Dx Universal Reaction Kit for Sequencing | S-1 FCM-D 100-D |
| S000499 | FASTASeq S Dx Universal Reaction Kit for Sequencing | S-1 FCM 100 |
| S000500 | FASTASeq S Dx Universal Reaction Kit for Sequencing | S-1 FCM 300 |
| S000531 | FASTASeq S Dx Universal Reaction Kit for Sequencing | S-2 FCL 600* |
| S000532 | FASTASeq S Dx Universal Reaction Kit for Sequencing | S-2 FCM 600* |
| S000579 | FASTASeq S Dx Universal Reaction Kit for Sequencing | S-3 FCH-D 100-D* |
| S000580 | FASTASeq S Dx Universal Reaction Kit for Sequencing | S-3 FCH 100* |
| S000581 | FASTASeq S Dx Universal Reaction Kit for Sequencing | S-3 FCH 300* |
*These sequencing reagents will be launched in Q1 2027.
**For in vitro diagnostic use. Not available in all countries.